Air Quality Monitoring Testing
DARLSCO with the team of Engineers/ experts cater’s to Environmental Monitoring, Testing and reporting of air pollutants including but not limited to (Respirable Suspended Particulate Matter (PM10), Total Suspended Particulate Matter (TSPM), Oxides of Nitrogen( NOx), Sulphur Dioxide( SO2), Carbon Monoxide(CO), Carbon dioxide (CO2), Ozone(O3) &TVOC. sampling and analysis of air quality parameters was carried out in accordance with the procedures described in USEPA 40 CFR Part No.50
Ambient Air Quality Monitoring and Testing
Ambient air quality speaks about the quality of outdoor air in our surrounding environment. It is typically measured near ground level, away from direct sources of pollution. The testing standards are including but not limited to USEPA 40CFR Part No:50, USEPA EQN-1277-026, USEPA EQN-0775-002, BS EN 60079-29, BS EN 14626 and with relevant NIOSH, ASTM, ASME, NCASI, CARB &SW846.
DARLSCO can perform Ambient Air Quality monitoring including but not limited to,
Sampling and Analysis of particulate matter (PM) in ambient air
Sampling and Analysis of Nitrogen Dioxide (NO2) in ambient air
Sampling and Analysis of Sulphur Dioxide (SO2) in ambient air
Sampling and Analysis of Ammonia (NH3) in ambient air
Sampling and Analysis of Hydrogen Sulphide (H2S) in ambient air
Sampling and Analysis of Carbon Monoxide (CO) in ambient air
Indoor Air Quality Monitoring and Testing
The Indoor Air quality Monitoring systems are sensor based instruments effective for Indoor and Industrial environments to sense/ measure the air pollutants namely Particulate Matter (PM), Determination of bio-aerosols in Indoor air, detection and enumeration of moulds based on standards including but not limited to NIOSH 0600, NIOSH 800, ISO 16000 and with relevant international standards of NIOSH, ASTM, ASME, NCASI, CARB & SW846.
Flue Gas Monitoring and Testing
The Flue gas monitoring of the Air pollutants will be carried out for Air pollutants including but not limited to SO2 from stationary sources and NO2 from stationary sources with the relevant standards USEPA-6C and USEPA-7E respectively.
Stack Emission Monitoring and Testing
The pollutants from Stack from single location of any facility, unit or activity will undergo stack test to determine the stack gas velocity, volumetric flow rate, particulate matter emission from stationary sources. The testing will be conducted based on standards USEPA-5 and with relevant standards NIOSH, ASTM, ASME, NCASI, CARB & SW846. The common emission sources are Stack monitoring of Paint booth, chimney and other domestic and Industrial applications.
Noise Quality and vibration Monitoring
Environmental noise monitoring is carried out to find out the allowable/acceptance limits of noise levels generated from source included but not limited to Industrial sources, Power stations, Construction activities, road &Traffic (line source), animals, aircraft noise and entertainment venues.
The monitoring of noise level follow the standard IEC 61672-1 and with relevant International standards.
Solid and Hazardous waste Testing and Reporting
Occupational Hygiene including but not limited to exposure monitoring to dust, fumes and other organic compounds
Environmental sampling and analysis - soil, Ground water and wastewater for metals, inorganic and organic compounds, TPHs, VOCs, SVOCs, pesticides, PAHs and PCBs etc.
Contaminated soil sites , water & microbiological investigation(s)